All membrane manufacturers recommend an SDI of less than 5 to prevent irreversible fouling of membranes.
In order to measure the degree of this fouling problem, a concept called silt density index or SDI is used. Here filtration rates are calculated by exposing a 0.45-micron filter to the feed water under pressure and filtration rates are calculated. With Aquacorp’s SDI test kits, you can get a clear measure of the degree of suspended solids and colloidal materials you have in your feed water.
In most cases, an SDI of less than 5 is considered acceptable for the reverse osmosis systems. Determining the SDI value would be instrumental in investigating relevant water purified technology or device which under ASTM method 4189-95 is generally accepted.
Features & Benefits
- Membrane holder MOC- Metal
- Membrane holder fitting quick connect
- Flexible hose fitting
- Rotating knobs to bleed air during testing
- Thickness of membranes : 85-110 um
- diameter of membrane : 47 mm