HOME              AQUACORP              WATERMART             MYRON L             CONTACT
Quality Water Treatment Equipment
from Australia's One Stop
Independent Wholesaler...
MYRON L  PRODUCTS
Accuracy You Can Trust

ULTRAPEN™ PT4 is Myron L® Company’s ground breaking, new Pocket Tester for measuring Free Chlorine Disinfecting Power, Free Chlorine Equivalent (FCE), as well as Temperature. It is waterproof and designed to be extremely accurate, fast, and simple to use in diverse water quality applications.

High Performance Features

  • Accuracy of up to ±0.3 ppm FCE
  • Proprietary Sensor Design
  • Calibration with pH and ORP Standard Solutions
  • Automatic Temperature Compensation
  • Temperature Readout
  • Waterproof
  • Powerd by one N Type Battery (included)

Applications

Agriculture Hydroponics Aquaculture Pharmaceutical Boilers and Cooling Towers Horticulture Wastewater Food and Beverage Irrigation Reverse Osmosis Plus Many More!

NEW! FCE Free Available Chlorine (FAC) Function

The Myron L® Company FCE function reports FAC quickly and accurately by measuring ORP, the chemical characteristic of chlorine that directly reflects its effectivity, cross referenced with pH. Both DPD kits and colorimeters may tell the user the FAC value of the sample in the test tube, but since the chemistry of that sample is quite different from the source water being analyzed, the results are imprecisely related to actual disinfection power. The Myron L® Company FCE function measures the real, unaltered chemistry of source water, including moment-to-moment changes in that chemistry.

Specifications
Copyright © 2015 Aquacorp Pty Ltd. All Rights Reserved.
ULTRAPEN PT4
Advanced Design Superior Perfomance












Free Chlorine Equivalent (FCE ™) & Temperature Pen












Package Contents

PT4 Pocket Test Pen - battery installed
Scoop
Pocket Clip
Holster
Lanyard
Operating Instructions

Accessories

Standard Solutions for calibration:
The ULTRAPEN™ PT4 requires pH4, pH7, and pH10 pH Buffer Solutions and 80 mV Quinhydrone, 260 mV Quinhydrone, or 470 mV MLC Light's ORP Standard Solutions for wet calibration, and Sensor Storage Solution for proper storage.
Order Model Numbers: ML-PH4, ML-PH7, ML-PH10, ML-ORP80, ML-ORP260, ML-ORP470, ML-ORPCALKIT, ML-PHSS.

Replacement pH Sensor:
The ULTRAPEN™ PT4 features a user replaceable FCE sensor. Installation instructions included with sensor.
Order model#: ML-RPT4

ORP Electrode Cleaning Paper:
Routinely cleaning the platinum electrode will keep the sensor free of build-up that can affect the speed and accuracy of FCE readings. Instructions for use are included with the paper.
Order model#s: ML-OECP-25 for QTY 25 or ML-OECP-100 for QTY 100

Warranty

The PT4, excluding the FCE sensor, has a one (1) year limited warranty. The FCE sensor has a six (6) month limited warranty.


Brochure and Operation Manual for Download

Ultrapen_PT4_ Data Sheet (includes specifications and options) PDF

Ultrapen_PT4_ Operation Manual PDF

Free Chlorine Equivalent
Temperature
Range:
0 - 10.0 ppm
0 - 71°C / 32 - 160°F
Accuracy:
< 5.00 ppm ± 0.3 ppm
= 5.00 ppm ± 0.5 ppm
± 0.1ºC / ± 0.1ºF
Resolution:
0.01 ppm
0.1ºC / 0.1ºF
Time to Reading Stabilization: 10 - 45 seconds      
Power Consumption: Active Mode 37 mA, Sleep Mode 2 µA   
Temperature Compensation: Automatic In Calibration Mode From 15ºC to 30ºC     
Physical Dimensions: 17.15 cm L x 1.59 cm D / 6.75 in. L x .625 in. D    
Weight: 50.4 g / 1.78 oz. (without soaker cap and lanyard)   
Case Material: Anodized Aircraft Aluminum with Protective Coating   
Battery Type: N type, Alkaline, 1.5V       
Calibration Standard Solutions: pH4, pH7, pH10, ORP80, ORP260, ORP470    
Operating/Storage Temperature: 0 - 55ºC or 32 - 131ºF       
Enclosure Ratings: IP67 and NEMA 6       
EN61236-1: 2006 – Annex A: 2008: Electrostatic discharge to the PT4 may cause it to
spontaneously turn on. If this occurs, the PT4 will turn off.